ORDERING CODE VOLTAGE (# OF LAMPS) LAMP TYPE
PRE-HEAT MAGNETIC FLUORESCENT BALLASTS (Starter Required)
* 1/F20 120V (1) F20T12, (1) F15T12,
(1) F15T8, (1) F14T12
* These items
will be deleted once our stock is depleted.
MAGNETIC FLUORESCENT BALLASTS
1/F17T8 120V (1) F17T8, (1) F16T8
1/F20 120V (1) F20T12, (1) F15T12,
(1) F15T8, (1) F14T12
1/F20 (-18 ˚C) COLD
START
120V (1) F20T12, (1) F15T12,
(1) F15T8, (1) F14T12
2/F20 120V (2) F20T12, (2) F15T12,
(2) F15T8, (2) F13T8
2/F20 (-18 ˚C) COLD
START
120V (2) F20T12, (2) F15T12,
(2) F15T8, (2) F13T8
* 2/F20 240V (2) F20T12, (2) F15T12,
(2) F15T8, (2) F13T8
2/F20 347V (2) F20T12, (2) F15T12,
(2) F15T8, (2) F13T8
1/F25T8 120V (1) F25T8
1/F30 SHORT 120V (1) F30T12, (1) FC12T9
1/F32T8 120V (1) F32T8, (1) F25T8, (1)
FB032T8, (1) FB031T8
1/F32T8 277V (1) F32T8, (1) F25T8, (1)
FB032T8, (1) FB031T8
1/F32T8 347V (1) F32T8, (1) F25T8, (1)
FB032T8, (1) FB031T8
2/F32T8 120V (2) F32T8, (2) F25T8, (2)
FB032T8, (2) FB031T8
2/F32T8 277V (2) F32T8, (2) F25T8, (2)
FB032T8, (2) FB031T8
2/F32T8 347V (2) F32T8, (2) F25T8, (2)
FB032T8, (2) FB031T8
1/F40 120V (1) F40T12, (1) F40T12/ES,
(1) F30T12
1/F40 (-18 ˚C) COLD
START
120V (1) F40T12, (1) F40T12/ES,
(1) F30T12
1/F40 Dimmable 120V (1) F40T12, (1) F40T12/ES,
(1) F30T12
1/F40 240V (1) F40T12, (1) F40T12/ES,
(1) F30T12
1/F40 277V (1) F40T12, (1) F40T12/ES,
(1) F30T12
1/F40 347V (1) F40T12, (1) F40T12/ES,
(1) F30T12
1/F40 (-18 ˚C) COLD
START
347V (1) F40T12, (1) F40T12/ES,
(1) F30T12
2/F40 120V (2) F40T12, (2) F40T12/ES,
(2) F30T12
2/F40 (-18 ˚C) COLD
START
120V (2) F40T12, (2) F40T12/ES,
(2) F30T12
2/F40 Dimmable 120V (2) F40T12, (2) F40T12/ES,
(2) F30T12
2/F40 240V (2) F40T12, (2) F40T12/ES
2/F40 277V (2) F40T12, (2) F40T12/ES,
(2) F30T12
2/F40 347V (2) F40T12, (2) F40T12/ES,
(2) F30T12
2/F40 (-18 ˚C) COLD
START
347V (2) F40T12, (2) F40T12/ES,
(2) F30T12
1/F42T6 120V (1) F42T6, (1) F48T12
2/F42T6 120V (2) F42T6
2/F48 Slimline 120V (2) F36T12, (2) F42T12,
(2) F48T12
1/F64T6 120V (1) F64T6, (1) F72T8, (1)
F72T12, (1) F96T12
2/F64T6 120V (2) F72T8, (2) F64T6
1/F96 (-18 ˚C) COLD
START
120V (1) F96T12, (1) F72T12,
(1) F64T12, (1) F60T12
ORDERING CODE VOLTAGE (# OF LAMPS) LAMP TYPE
2/F96 120V (2) F96T12, (2) F96T12/ES,
(2) F84T12, (2) F72T12, (2) F64T12
2/F96 277V (2) F96T12, (2) F96T12/ES,
(2) F84T12, (2) F72T12, (2) F64T12
2/F96 347V (2) F96T12, (2) F96T12/ES,
(2) F84T12, (2) F72T12, (2) F64T12
2/F96 600V (2) F96T12, (2) F96T12/ES,
(2) F84T12, (2) F72T12, (2) F64T12
* These items
will be deleted once our stock is depleted.
MAGNETIC HIGH OUTPUT BALLASTS
2/F48 120V HO (2) F48T12/HO, (2) F84T12/HO,
(2) F72T12/HO, (2) F64T12/HO
2/F48 120V VHO (2) F48T12/HO, (2) F84T12/HO,
(2) F72T12/HO, (2) F64T12/HO
2/F48 240V HO (2) F48T12/HO, (2) F84T12/HO,
(2) F72T12/HO, (2) F64T12/HO
2/F48 347V HO (2) F48T12/HO, (2) F84T12/HO,
(2) F72T12/HO, (2) F64T12/HO
2/F96 120V HO (2) F96T12/HO, (2) F84T12/HO,
(2) F72T12/HO
2/F96 120V VHO (2) F96T12/HO, (2) F84T12/HO,
(2) F72T12/HO
2/F96 240V HO (2) F96T12/HO, (2) F84T12/HO,
(2) F72T12/HO
2/F96 347V HO (2) F96T12/HO, (2) F84T12/HO,
(2) F72T12/HO
2/F96 600V HO (2) F96T12/HO, (2) F84T12/HO,
(2) F72T12/HO
SIGN BALLASTS
348AT 120V (2-3) 4 ft. min. – 12 ft.
max.
348AT 347V (2-3) 6 ft. min. – 12 ft.
max.
372AT 120V (2-3) 12 ft. min. – 18
ft. max.
372AT 347V (2-3) 12 ft. min, – 18
ft. max.
396AT 120V (2-3) 10 ft. min. – 24ft.
max.
396AT 347V (2-3) 12 ft. min. – 24
ft. max.
448AT 120V (2-4) 8 ft. min. – 16 ft.
max.
464AT 120V (2-4) 10 ft. min. – 22
ft. max.
472AT 120V (2-4) 12 ft. min. – 24
ft. max.
472AT  347V (2-4) 12 ft. min. – 24
ft. max.
496AT 120V (2-4) 16 ft. min. – 32
ft. max.
496AT 347V (2-4) 16 ft. min. – 32
ft. max.
4120AT 120V (2-4) 20 ft. min. – 40
ft. max.
572AT 120V (5-6) 15 ft. min. – 30
ft. max.
648AT 120V (4-6) 10 ft. min. – 26
ft. max.
672AT 120V (4-6) 20 ft. min. – 36
ft. max.
672AT 347V (4-6) 18 ft. min. – 36
ft. max.
696AT 120V (4-6) 24 ft. min. – 48
ft. max.
696AT 347V (4-6) 24 ft. min. – 48
ft. max.
NEON SIGN BALLASTS
425B 120V
ORDERING CODE VOLTAGE (# OF LAMPS) LAMP TYPE
ELECTRONIC FLUORESCENT BALLASTS
INSTANT START
2/F17T8 120V (1) F17T8, (2) F17T8, (1)
F25T8
1/F32T8 120V (1) F32T8, (1) FB32T8,
(1) F25T8, (1) F40T8, (1) F17T8
1/F32T8
Dimmable
120V (1) F32T8, (1) FB32T8,
(1) F25T8, (1) F40T8, (1) F17T8
1/F32T8 347V (1) F32T8, (1) FB32T8,
(1) F25T8, (1) F40T8, (1) F17T8
2/F32T8 120V (1) F32T8, (2) F32T8, (2)
F25T8, (2) F17T8, (1) F40T8, (1) 40/22T5
2/F32T8
Dimmable
120V (1) F32T8, (2) F32T8, (2)
F25T8, (2) F17T8, (1) F40T8, (1) 40/22T5
2/F32T8 240V (1) F32T8, (2) F32T8, (2)
F25T8, (2) F17T8, (1) F40T8, (1) 40/22T5
2/F32T8 277V (1) F32T8, (2) F32T8, (2)
F25T8, (2) F17T8, (1) F40T8, (1) 40/22T5
2/F32T8 347V (1) F32T8, (2) F32T8, (2)
F25T8, (2) F17T8, (1) F40T8, (1) 40/22T5
3/F32T8 120V (3) F32T8, (3) FB32T8,
(3) F25T8, (3) F17T8, (2) F40T8
3/F32T8
Dimmable
120V (3) F32T8, (3) FB32T8,
(3) F25T8, (3) F17T8, (2) F40T8
3/F32T8 240V (3) F32T8, (3) FB32T8,
(3) F25T8, (3) F17T8, (2) F40T8
3/F32T8 277V (3) F32T8, (3) FB32T8,
(3) F25T8, (3) F17T8, (2) F40T8
3/F32T8 347V (3) F32T8, (3) FB32T8,
(3) F25T8, (3) F17T8, (2) F40T8
4/F32T8 120V (4) F32T8, (4) FB32T8,
(4) F25T8, (4) F17T8, (3) F32T8
4/F32T8 240V (4) F32T8, (4) FB32T8,
(4) F25T8, (4) F17T8, (3) F32T8
4/F32T8 277V (4) F32T8, (4) FB32T8,
(4) F25T8, (4) F17T8, (3) F32T8
4/F32T8 347V (4) F32T8, (4) FB32T8,
(4) F25T8, (4) F17T8, (3) F32T8
2/F96T8 120V (2) F96T8, (1) F96T8
2/F96T8 347V (2) F96T8, (1) F96T8
HIGH OUTPUT
2/F96T8 H.O. 120V (2) F96T8/HO, (1) F96T8/HO
RAPID START
2/F32T8 120V (2) F32T8, (2) FB32T8
2/F32T8 DIMMABLE 120V (2) F32T8, (2) FB32T8
2/F32T8 240V (2) F32T8, (2) FB32T8
2/F32T8 347V (2) F32T8, (2) FB32T8
4/F32T8 120V (4) F32T8, (4) FB32T8,
(4) F25T8
4/F32T8 347V (4) F32T8, (4) FB32T8,
(4) F25T8